Rated capacity: 25 Ah (1-hour rate discharge).
2.2 Nominal voltage: 24V.
2.3 Maximum weight: 24.36 kg (charged electrolyte).
2.4 Maximum external dimensions: 370 mm × 174 mm × 229 mm.
The electrolyte temperature is -10 ℃, and it should be started three times. The termination voltage for the third start should not be lower than 16V
Charging for work
The battery pack should be charged according to maintenance card 3, and during the charging process, it should be checked according to maintenance card 6
Check and adjust the electrolyte level, and clean and drain the removed assembly air plug according to maintenance card 15
Air pressure check, after charging is completed, handle according to maintenance card 9 for outdoor use